Axiom Pro User Guide
Loading Patches:
To load a saved patch:
1 Press the Load button The button becomes illuminated and the Load page is displayed on the LCD
2 Turn Encoder knob E5 to select the patch that you would like to load
✓
TIP:
Axiom Pro 49/61 users can also use the +/- buttons or enter the patch number using the
numerical keypad
3 By default, all of the controller groups of Axiom Pro (i e , the encoder knobs, drum
pads, etc ) will be loaded from the saved patch If you would like to load a new
patch but keep the current settings of a group:
a Axiom Pro 49/61 users: Press the “N,” “S,” “E,” and “P” buttons
3
to uncheck
the Number, Slider, Encoder, and Pad groups Axiom Pro 25 users: Press
the Record and Play buttons to uncheck the encoder and pad groups,
respectively
b Use Soft Keys 2-3 to uncheck the Keyboard and Transport Control groups,
respectively
4 Press Soft Key 4 (Load) to load the patch and return to Performance mode
Soft Key 1 (Exit) can be pressed at any time to exit this page without loading a
patch
3
NOTE: Since Axiom Pro 25 does not feature sliders (“S”) or a numerical keypad (“N”), these groups will not appear on
the Load Page.
When a new Axiom Pro
patch is recalled, the Program
change and Bank LSB/
MSB settings of the newly
loaded patch are also
recalled. If you would like to
load a new Axiom Pro patch
without transmitting Program
Change and Bank LSB/MSB
messages, use Soft-Key 2
to ensure that the keyboard
group is not checked.