beautypg.com

Troubleshooting guide – Graco Inc. 223660 User Manual

Page 10

background image

10

307-730

TROUBLESHOOTING GUIDE

Pressure Relief Procedure

To reduce the risk of serious bodily injury, including

injury from moving parts, or electric shock, always

follow this procedure whenever you shut off the sys-

tem, when checking or servicing any part of the sys-

tem and whenever you stop painting.
1. Turn the ON/OFF switch to OFF.

2. Unplug the power supply cord.

3. Trigger the roller valve to relieve pressure.

If you suspect that pressure is not fully relieved after

following the steps above, open the priming valve 2

turns counterclockwise.

WARNING

CAUTION

Thoroughly flush the system after each use to re-

duce down time and costly repair bills.

NOTE: If you are not able to determine the cause of the

problem, or the problem and solution is not dis-

cussed in this chart, return the system to an au-

thorized service agency for repair.

PROBLEM

CAUSE

SOLUTION

Pump will not prime, or takes long time to prime Clogged suction tube filter

Clean.

Paint too thick

Thin; try pouring paint into suction tube.

Outlet valve spring worn or damaged

Pour paint into suction tube and try to prime system.

If it doesn’t prime in one minute, replace the outlet

spring. See Outlet Valve, page 13.

Inlet valve stuck or damaged

Depress valve gently and pour in about 1 teaspoon

mineral spirits. Try to prime pump. Replace valve if

necessary. See Inlet Valve, page 13.

Й

Й

З

З

Й

Й

З

З

0289

DEPRESS LIGHTLY.

POUR IN 1 TEASPOON

MINERAL SPIRITS.

Loose inlet hose nut

Tighten

Pump will not start

Power cord unplugged

Plug in.

ON/OFF switch turned off

Turn on.

Damaged motor

Replace. See page 15.

Fuse burned out.

Replace. See page 12. If it burns out again soon, re-

turn the system to an authorized repair agency for re-

pair.

Low or no paint flow

Clogged roller cover , diffuser, roller frame,

roller valve, or hose

Clean thoroughly after each use. See Flushing on

page 8.

Using more than 25 ft. (7.6 m) of 1/4” ID hose Use up to 100 ft. (30 m) of 3/8” ID hose. See CAU-

TION on page 2.

Loose inlet hose nut

Tighten.

Worn or damaged priming valve

Replace. See page 14.

Priming valve is open

Close.

Paint too thick

Thin: Follow manufacturer‘s recommendations.

Damaged pressure switch

Replace. See page 13.

Worn inlet and/or outlet valve

Replace. See page 13.

Pump runs after roller valve trigger is released Worn or damaged pressure switch

Replace. See page 13.

Worn or damaged inlet valve

Replace. See page 13.

Worn or damaged outlet valve

Replace. See page 13.

Worn or damaged priming valve

Replace. See page 14.

Worn roller valve packings or needle

Repair. See page 11.

This manual is related to the following products: