Manual switch-selections and jumpers

Fiber default: 100Mbps Full-duplex, F/H (Full/ Half duplex switch

settings)

Copper default: Auto-negotiation (Up-link switch for cascading at port #1,

(=) for normal port and (X) for an upstream cascaded hub or

switch

LEDs: Per Port

L/A:

Steady ON for Link enabled, blinking indicates Activity, port

is transmitting and receiving

F/H: ON = Full-Duplex Mode

OFF = Half-Duplex Collision

100/10: ON = 100Mbps speed

OFF = 10 Mbps

Operating

Environment

Ambient Temperature: 25

° to 140° F (-5° to 60°C) optional extended range

Storage Temperature: -40

°to 185°F (-40°to 85°C)

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude: -200 to 13,000 ft. (-60 to 4000m)

Packaging

Enclosure: Rugged High strength metal. Suitable for stand-alone or

rack-mounting

Dimensions: 1.75 in H x 17.0 in W x 9.0 in D

4.45cm H x 43.2cm W x 22.9cm D

Weight:

3.2 lb. (1.4 Kg) rack-mount models

Cooling method: Fan cooled, @ 7 cfm

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed at rear of chassis,

with adjacent manual ON-OFF switch (on AC models only)

Input Voltage: 110 to 240 VAC (auto-ranging)

Input Frequency: 47 to 63 Hz (auto-ranging)

Power Consumption: 17 watts typical, 25 watts max.

DC Power Supply (Options)

-48VDC Power Input Voltage : 36 to 72 VDC
24VDC Power Input Voltage : 20 to 36VDC
125VDC Power Input Voltage : 120 to 160VDC
Std. Terminal Block : “ -, GND, + ”

Power Consumption: same as for AC models, see above

For Dual Source and Redundant DC for –48VDC, 24VDC Power
& 125VDC supply options (Optional), see Appendices.

Agency Approvals

UL listed (UL1950), cUL, CE

Emissions meet FCC Part 15 Class B

Optional: ETSI and NEBS L3 Certified

Warranty Three years, return to factory

Made in USA