www GarrettCom com

.

.


Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

where the “Cable Loss” for 62.5/125 and 50/125

µm

(M.m) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km


The following data has been collected from component manufacturer’s (HP’s and
Siemens’) web sites and catalogs to provide guidance to network designers and installers.

Fiber

Port

Module

Speed,

Std.

Mode

Std.

km
fdx

(hdx)

Wave

-

length

nm

Cable

Size

µm

X’mitr

Output

P

T ,

dB

R’cvr

Sens.

P

R ,

dB

Worst

OPB,

dB

Worst*

distance
Km, fdx

typical

OPB,

dB

typical*

distance
Km, fdx

FKM-

MST, MSC

100Mb

FX

Multi-

mode

2

(0.4)

1300

62.5/125

50/125

-20

-23.5

-31

-31

9.0

5.5

2.5

2.0

14

12

5

4

FKM-SSC

100Mb

FX

Single-

mode

18+

(0.4) 1300

9/125 -15 -31 14 28

17.5 35

FKM-
MTRJ

100Mb

FX

Multi-

mode

2

(0.4)

1300

62.5/125

50/125

-20

-23.5

-31

-31

9.0

5.5

3.0

2.0

15.8

12.2

5.5

4.0

FKM-SSCL 100Mb

FX

Single-

mode

40

(0.4) 1300

9/125 -5 -34 29 58 32.5 65


* Not
e: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed

over long distances (i.e., in excess of approx. 400 meters) can be achieved

only

if the following factors are both applied:

The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
and

The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)