beautypg.com

GarrettCom 4K16 User Manual

Page 16

background image

Magnum 4K16 Switches Installation and User Guide

(12/05)

10

www GarrettCom com

.

.

provide maximum network performance with the least dropped packets.

When the Switch detects that its free buffer queue space is low, the Switch

sends industry standard (full-duplex only) PAUSE packets out to the devices sending

packets to cause “flow control”. This tells the sending devices to temporarily stop

sending traffic, which allows a traffic catch-up to occur without dropping packets. Then,

normal packet buffering and processing resumes. This flow-control sequence occurs in a

small fraction of a second and is transparent to an observer. See Section 4.6 for

additional details.

Another feature implemented in Magnum 4K16 Switches is a collision-based

flow-control mechanism (when operating at half-duplex only). When the Switch detects

that its free buffer queue space is low, the Switch prevents more frames from entering by

forcing a collision signal on all receiving half-duplex ports in order to stop incoming

traffic.

The latency (the time the frame spends in the Switch before it is sent along or

forwarded to its destination) of the 4K16 Switches varies with the port-speed types, and

the length of the frame is a variable here as it is with all store-and-forward switches. The

4K16 Switch’s latency is 5 microseconds plus the packet time at 100Mb. See Section 1.1

Specifications.