beautypg.com

Emergency stop, Auxiliary controls, Operation from ground – Genie Z34N-2100 Z-34 User Manual

Page 23

background image

Part No. 43654

Genie Z-34/22 & Genie Z-34/22N

21

Operator's Manual

Second Edition • Ninth Printing

OPERATING INSTRUCTIONS

Emergency Stop

Push in the red Emergency Stop button to the off
position at the ground or platform controls to stop
all machine functions.

Repair any function that operates when the red
Emergency Stop button is pushed in.

Selecting and operating the ground controls will
override the platform Red Emergency Stop button.

Auxiliary Controls

Use auxiliary power if the primary power source
fails.

1 Turn the key switch to ground or platform

control.

2 Pull out the red Emergency Stop button to the

on position.

3 Move the lift/drive select switch to the

appropriate position (if equipped) when
operating the auxiliary controls from the
platform.

4 Press down the foot switch when operating the

auxiliary controls from the platform.

5 Simultaneously hold the auxiliary power switch

on and activate the desired function.

The boom, steer and drive functions will operate
with auxiliary power.

Operation from Ground

1 Turn the key switch to ground control.

2 Pull out the red Emergency Stop button to

the on position.

3 Be sure both battery packs are connected

before operating the machine.

To Position Platform

1 Hold the function enable switch to either side.

2 Move the appropriate toggle switch according

to the markings on the control panel.

Drive and steer functions are not available from the
ground controls.

Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the boom is raised past the
drive speed limit switch.