beautypg.com

Pressure control – Graco Inc. 232632 User Manual

Page 13

background image

308870

13

Pressure Control

Control Board

Removal

1.

Relieve pressure

; page 4.

2. Fig. 15. Remove five screws (307) and

cover (322).

3. Fig. 22. Disconnect at control board (302):

D Four clutch leads: two violet and two black.
D Lead (D) from potentiometer.
D Lead (E) from transducer.

D Two red leads (A) to ON/OFF switch (309).

4. Fig. 15. Remove five screws (303), green ground

wire and control board (302).

Installation
When installing replacement control board, follow

instructions with control board to set model type.

1. Fig. 15. Install green ground wire and control

board (302) with five screws (303).

2. Fig. 22. Connect to control board (302):

D Two red leads (A) to ON/OFF switch (309).
D Lead (E) to transducer.
D Lead (D) to potentiometer.
D Four clutch leads: two violet and two black.

3. Fig. 15. Install cover (322) with five screws (307).

Pressure Control Transducer

Removal

1.

Relieve pressure

; page 4.

2. Fig. 15. Remove five screws (307) and

cover (322).

3. Disconnect lead (E) from control board (302).
4. Remove three screws (319) and fluid filter (318)

from control plate (301). Carefully pull transducer

connector through rubber grommet (315).

5. Remove pressure control transducer (318z) and

packing o-ring (318aa) from filter housing (318a).

Installation
1. Fig. 15. Install packing o-ring (318aa) and pres-

sure control transducer (318z) in filter

housing (318a). Torque to 30–35 ft-lb.

2. Carefully feed transducer connector through

rubber grommet (315). Install fluid filter (318) on

control plate (301) with three screws (319).

3. Connect lead (E) to motor control board (302).
4. Install cover (322) with five screws (307).

Pressure Adjust Potentiometer

Removal

1.

Relieve pressure

; page 4.

2. Fig. 15. Remove five screws (307) and

cover (322).

3. Disconnect lead (D) from control board (302).
4. Loosen set screws on potentiometer knob (313)

and remove knob, shaft nut, lockwasher (310) and

pressure adjust potentiometer (310).

5. Remove seal (311) from potentiometer (310).

Installation
1. Install seal (311) on potentiometer (310).
2. Fig. 15. Install pressure adjust potentiometer

(310), shaft nut, lockwasher (310) and potentiome-

ter knob (313).
a. Turn potentiometer shaft (310) clockwise to

internal stop. Assemble potentiometer knob

(313) to strike pin on plate (312).

b. After adjustment of step a., tighten both set

screws in knob 1/4 to 3/8 turn after contact

with shaft.

3. Connect lead (D) to control board (302).