G9749 Variable Speed Drill Press

-9-

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the setup pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110/220V Operation

SECTION 2: CIRCUIT REQUIREMENTS

Amperage Draw

The Model G9749 features a 110/220V motor
that is prewired for 220V and draws the following
amps under maximum load:

Motor Draw at 110V .............................. 16 Amps
Motor Draw at 220V ............................... 8 Amps

Circuit Requirements

We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri-
cian to ensure compliance with wiring codes.

If

you are unsure about the wiring codes in your

area or you plan to connect your machine to a

shared circuit, consult a qualified electrician.

110V Circuit ...........................................30 Amps
220V Circuit ...........................................20 Amps

Plug/Receptacle Type

We recommend using one of the following plugs
for your machine on a dedicated circuit only (see
Figures 3 & 4 for examples):

110V Plug & Receptacle ............................ L5-30
220V Plug (provided) & Receptacle .............6-15

Figure 4. 6-15 plug and receptacle.

Figure 3. L5-30 plug and receptacle.

NOTICE

The Model G9749 is prewired for 220V oper-

ation. If you plan to rewire your machine

for 110V, you must change the motor wir-

ing, plug, and power receptacle. Consult

a qualified electrician before attempting to

rewire your machine!