beautypg.com

Galil DMC-2X00 User Manual

Page 23

background image

ICM-2900

ICM-2908

ICM-2900

0

1

3

2

7

6

4

5

IOM-1964-80

GALIL

Power Cable (Included

with the controller)

ICM-2900
Provides Connection to
Signals for Axes E-H

ICM-2908
Provides Connection to All
Auxiliary Encoder Signals

CABLE-36-1M (1METER)

OR

CABLE-36-4M (4METER)

CABLE-100-1M

OR

CABLE-100-4M

Cable 9-PinD

Main Serial Port to

Computer

Auxiliary Serial Port

Connection

(System Dependent

Cable)

ICM-2900
Connection to
Signals for Axes A-D

IOM-1964-80

Provides Opto-Isolation

and Interconnection for

Extended I/O

DMC-2000

CABLE-80-1M (1Meter)

OR

CABLE-80-4M (4Meter)

100/10 BASE-T

Cable

Figure 2-5 Recommended System Elements of DMC-2100/DMC-2200

For a complete system, Galil recommends the following elements:

1a. DMC-2x10, 2x20, 2x30, or DMC-2x40 Motion Controller

or

1b. DMC-2x50, 2x60, 2x70 or DMC-2x80

2a. (1) ICM-2900 and (1) CABLE-100 for controllers DMC-2x10 through DMC-2x40

or

2b. (2) ICM-2900's and (2) CABLE-100’s for controllers DMC-2x50 through DMC-2x80.

or

2c. An interconnect board provided by the user.

3. (1) IOM-1964 and (1) CABLE-80 for access to the extended I/O. Only required if extended

I/O will be used. The CABLE-80 can also be converted for use with OPTO-22 or Grayhill
I/O modules - consult Galil.

4. (1) ICM-2908 and (1) CABLE-36 for access to auxiliary encoders. Only required if auxiliary

encoders are needed.