GENERAL SAFETY
PROPER LOAD CHART USE
2 - 10
PO Box 97030
18340 NE 76th St
Redmond WA 98073
Manufacturer's recommended capacity is
per ANSI B56.6 Stability Tests using
standard homogeneous cubes 4 x 4 x 4 ft /
1.2 x 1.2 x 1.2 m.
Load capacities at 24 in / 60 cm load center
with standard fork frame.
Rated lift capacities shown are with
machine on a firm level surface with
undamaged, properly inflated calcium
chloride solution filled tires or optional foam
filled tires. Rear axle lock-up engaged.
Load Limits / Horizontal Boom
Front Stabilizers Up
Last Fully Visible Letter
Retracted
10,000 lbs
A Letter Visible
8000 lbs
B Letter Visible
4000 lbs
C Letter Visible
2000 lbs
D Letter Visible
1000 lbs
E Letter Visible
500 lbs
*Front Stabilizers Down
Last Fully Visible Letter
Retracted
10,000 lbs
A Letter Visible
8000 lbs
B Letter Visible
6000 lbs
C Letter Visible
4000 lbs
D Letter Visible
2000 lbs
E Letter Visible
2000 lbs
PO Box 97030
18340 NE 76th St
Redmond WA 98073
Manufacturer's recommended capacity is
per ANSI B56.6 Stability Tests using
standard homogeneous cubes 4 x 4 x 4 ft /
1.2 x 1.2 x 1.2 m.
Load capacities at 24 in / 60 cm load center
with standard fork frame.
Rated lift capacities shown are with
machine on a firm level surface with
undamaged, properly inflated calcium
chloride solution filled tires or optional foam
filled tires. Rear axle lock-up engaged.
Load Limits / Horizontal Boom
Front Stabilizers Up
Last Fully Visible Letter
Retracted
10,000 lbs
A Letter Visible
8000 lbs
B Letter Visible
6000 lbs
C Letter Visible
4000 lbs
D Letter Visible
2500 lbs
E Letter Visible
2000 lbs
*Front Stabilizers Down
Last Fully Visible Letter
Retracted
10,000 lbs
A Letter Visible
9000 lbs
B Letter Visible
7000 lbs
C Letter Visible
6000 lbs
D Letter Visible
4000 lbs
E Letter Visible
3000 lbs