GE WBVH6240 User Manual
Page 54

Error Code
Description
Problem
Possible Cause/Action
E43
DC Fault -
Inverter
Inverter failure.
Non-recoverable error.
Replace inverter control board.
•
•
E45
Drive motor -
overload current
Load too
heavy.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check mechanical faults - check belt, basket,
bearing - rotate basket by hand.
Power down (unplug) washer, wait 30 seconds and
retry - if reoccurs, replace inverter. (Note: Cannot
occur with open winding.)
•
•
•
E46
Drive motor -
over temperature
Inverter over
temperature.
Check Motor - t10 tumble, t11 spin, T14 spin.
Power down (unplug) washer, wait 30 seconds and
retry - use whites cycle sanitize temperature - if
reoccurs, replace drive motor. (Note: Cannot occur
with open winding.)
•
•
E47
Heat sink - over
temperature
Inverter over
temperature.
Check Motor - t10 tumble, t11 spin, T14 spin.
Power down (unplug) washer, wait 30 seconds and
retry - use whites cycle sanitize temperature - if
reoccurs, replace drive motor. (Note: Cannot occur
with open winding.)
•
•
E48
Drive motor
- open
Open motor
phase.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check motor for open winding - if OK, replace
inverter. (Note: Occurs with open winding.)
•
•
E49
Drive motor -
overload power
Load too
heavy.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check mechanical faults (binding) - belt, basket,
bearing - rotate basket by hand.
Check motor for shorted winding - if OK, replace
inverter.
Power down (unplug) washer, wait 30 seconds and
retry - if reoccurs, replace inverter. (Note: Cannot
occur with open winding.
•
•
•
•
E4A
Under volts
Under volts -
DC bus voltage
(inverter).
Check Motor - t10 tumble, t11 spin, T14 spin.
Power down (unplug) washer, wait 30 seconds and
retry - if reoccurs, replace inverter. (Note: Cannot
occur with open winding.)
•
•
E4B
Power up
problems
Software/
hardware
problems.
Check Motor - t10 tumble, t11 spin, T14 spin.
Check motor windings - internal short
Power down (unplug) washer, wait 30 seconds and
retry - if reoccurs, replace inverter. (Note: Cannot
occur with open winding.)
•
•
•
E4C
Over volts
Over volts - DC
bus (inverter).
Check Motor - t10 tumble, t11 spin, t14 spin.
Power down (unplug) washer, wait 30 seconds and
retry - if reoccurs, replace inverter. (Note: Cannot
occur with open winding.)
•
•
(Continued Next Page)