Notice – Grizzly G0561 User Manual
Page 11

g0561 7" x 12" Metal-Cutting Bandsaw
-9-
Serious personal injury could occur if you
connect the machine to power before com-
pleting the setup process. DO NOT connect
the machine to the power until instructed
later in this manual.
110/220v Operation
SECTION 2: CIrCUIT rEQUIrEMENTS
full Load Amperage Draw
Amp draw at 110v (prewired) ................ 16 Amps
Amp draw at 220v ..................................8 Amps
power Supply Circuit requirements
you Must connect your machine to a grounded
circuit that is rated for the amperage given below.
never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes.
If you are unsure about the
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult
a qualified electrician.
Minimum Circuit size (110v) ..................20 Amps
Minimum Circuit size (220v) ................. 15 Amps
power Connection Device
the Model g0561 comes prewired with a neMA
5-15 plug for connection to power. if you rewire the
motor to 220v, we recommend using the plug and
receptacle shown in
figure 2 for 220v.
Extension Cords
using extension cords may reduce the life of the
motor. instead, place the machine near a power
source. if you must use an extension cord:
•
For 110v, use at least a 12 gauge cord that
does not exceed 50 feet in length.
•
For 220v, use at least a 14 gauge cord that
does not exceed 50 feet in length.
•
the extension cord must have a ground wire
and plug pin.
Electrocution or fire could
result if machine is not
grounded and installed in
compliance with electrical
codes. Compliance MUST
be verified by a qualified
electrician!
figure 2. recommended plug types.
5-20 plug & outlet
for 110v
6-15 plug & outlet
for 220v
NOTICE
The ModeL G0516 is prewired for 110v oper-
ation. If you plan to operate your machine
at 220v, the motor must be rewired (see
page 40).