9

After loading all charts desired, the chart

conversion (from ENC to SENC) automatically

starts.

8. At this time, the message [No Base Cell

available] and chart cell numbers are displayed

in the [S57 LOAD] window. Then, place the

cursor on the [OK] button and press the

[SELECT] key.

The chart CD-ROM which is issued by the

Hydrographic Department, Maritime Safety

Agency of Japan contains all chart data, but

there are some areas which the base charts cell

(last three digits of chart number : 000) are not

installed in the ECDIS. These chart cell numbers

are displayed.

9. If the message [Update number is too low] and

chart cell numbers are displayed in the [S57

LOAD] window, place the cursor on the [OK]

button and press the [SELECT] key

This message means that the ECDIS does not

update older version charts contained in the

CD-ROM.

For example, if the lower three digits of the chart

numbers are 001 to 028, 001 - 015 are not

updated (not used) and 016 - 028 are updated.

The chart cell numbers to be updated are displayed

in the [Conversion list] on the [SENC CONVERT]

window. The chart is updated cell by cell from the

top of the list. After the conversion has been

completed, the chart numbers disappear from the

window. Further the color of a chart cell frame

changes to green when conversion of the cell is

completed. The conversion may take 4 - 5 hours,

depending on the quantity of chart numbers

installed.

[Update number is too low]

[No Base Cell available]

Chart cell number

[S57LOAD] window

[SENC CONVERT] window