beautypg.com

Panel test – Furuno FCV-1200LM User Manual

Page 77

background image

5-5

Program No.

0252296-0XX

Panel Unit

Ver XX OK

R O M

OK

S R A M

OK

D R A M

OK

E S 1

OK

15-200*

E S 2

OK

15-200*

E X I F

OPEN

N M E A

OK

SONDE (CIF)

OK

Temp. SENSOR +32.6˚F

Temp. SONDE

+31.6˚F

Press and hold [MARKER] key more than 3 sec to exit.

XX: Version No.

*

: Frequency from the transducer connected.

*

0

0

61

0

8

0

5

0

0

0

0

86

ROM, SRAM, DRAM test results are shown as OK or NG (No Good).

ES1, ES2: ES1/2 Board connection test results are shown as OK or OPEN. (For

FCV-1200LM, OPEN only.) When test result is OK, the frequency of ES Board appears;

15-200 or 400.

EXIF: Test results are shown as OK or OPEN (no EXIF assy connection). For FCV-1200LM,

OK appears.

NMEA*, SONDE (CIF)* test results are shown as OK. Nothing appears in case of error or no

connection. *requires special test connector.

Panel test

The “Panel” column at the right of the diagnostics display is used to check keys and controls.

1. Press any key except the [POWER] key. The pressed key’s on-screen location changes

from 0 to 1 when the key is pressed.

2. Operate the controls. For the controls the figure on the screen changes as below.

[FUNCTION] :1 to 8

[RANGE] :

0 to 20

[MODE] :

1 to 7

[GAIN] :

0 to 127

3. Press the [MARKER/TLL] key more than three seconds to return to the SYSTEM menu.

4. Rotate the [FUNCTION] switch fully counterclockwise to select EXIT.