3-9

3.5 TEMP SETTING Menu

This menu sets up water temperature sensor.

DISP ALM TX/RX USER-1/2

SYSTEM

Select temperature sensor.

[-/+]: Change set, [EXIT (knob)]: Exit

TEMP SETTING

TEMP INPUT

:

SENSOR

TEMP ADJUST : +0.0 F(-20 +20)

TEMP READOUT : ON
TEMP GRAPH : OFF
TEMP COLOR : STD

TEMP SETTING menu

TEMP INPUT

Selects source of water temperature data; net sonde, sensor, NMEA or CIF.

TEMP ADJUST

Offsets water temperature indication to improve accuracy. Effective only for net sonde and water

temperature sensor. (-20.0 to +20.0

°

F in 0.1 step)

TEMP READOUT

Turns on/off water temperature indication.

TEMP GRAPH

Turns on/off temperature graph and selects graph scale.

OFF: No water temperature graph

NARROW: Graduation every 2

°

STD: Graduation every 2.5

°

(default setting)

EXPAND: Graduation every 5.0

°

TEMP COLOR

Selects the color of the temperature graph (standard, white, red, black, yellow).

Note: Standard means the fifth color from the bottom of the color bar, including background

color in 16-color display; third color in 8-color display. Yellow means tenth (8-color display: sixth)

color from the bottom of the color bar.