Frymaster LOV BIELA14 User Manual
Page 42

1-35
1.14.4 Error Log Codes
Refer to page 1-39, level 2 program for access to the E-log. The ten most recent errors are listed from
A-J, with A being the most recent error.
Code ERROR
MESSAGE
EXPLANATION
E01
REMOVE DISCARD (Right)
A product cook is started on the right side of a split
vat or in a full vat that has a different setpoint other
than the current vat temperature.
E02
REMOVE DISCARD (Left)
A product cook is started on the right side of a split
vat or in a full vat that has a different setpoint other
than the current vat temperature.
E03
ERROR TEMP PROBE FAILURE
Temp probe reading out of range
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than 410
°F
(210
°C), or in CE countries, 395°F (202°C)
E06
HEATING FAILURE
A component has failed in the high limit circuit such
as computer, interface board, contactor or open-
high limit.
E07
ERROR MIB SOFTWARE
Internal MIB software error
E08
ERROR ATO BOARD
MIB detects ATO board connection lost; ATO
board failure
E09
ERROR PUMP NOT FILLING
Oil not returning to vat quickly. Possible problems:
dirty pad, bad or missing O-rings, tripped or
defective filter pump, actuators or linkage.
E10
ERROR DRAIN VALVE NOT OPEN
Drain valve failed to open; the valve’s position is
unknown.
E11
ERROR DRAIN VALVE NOT CLOSED
Drain valve failed to close; the valve’s position is
unknown.
E12
ERROR RETURN VALVE NOT OPEN
Return valve failed to open; the valve’s position is
unknown.
E13
ERROR RETURN VALVE NOT CLOSED
Return valve failed to close; the valve’s position is
unknown.
E14
ERROR AIF BOARD
MIB detects AIF missing; AIF board failure
E15
ERROR MIB BOARD
Cooking computer detects MIB connections lost;
Check software version on each computer. If
versions are missing, check CAN connections
between each computer; MIB board failure
E16
ERROR AIF PROBE
AIF RTD reading out of range
E17
ERROR ATO PROBE
ATO RTD reading out of range
E18
Not currently used
E19
M3000 CAN TX FULL
Connection between computers lost
E20
INVALID CODE LOCATION
SD card removed during update
E21 FILTER PAD PROCEDURE ERROR
(Change Filter Pad)
25 hour timer has expired or dirty filter logic has
activated
E22
OIL IN PAN ERROR
The MIB has reset the oil in pan flag.
E23
CLOGGED DRAIN (Gas)
Vat did not empty during filtration
E24
AIF BOARD OIB FAILED (Gas)
Oil is back sensor failed.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E26
RECOVERY FAULT CALL SERVICE
Recovery time exceeded maximum time limit for
two or more cycles.
E27
LOW TEMP ALARM
Oil temperature has dropped lower than 15°F (8°C)
in idle mode or 45°F (25°C) in cook mode.