Frymaster LOV BIELA14 User Manual
Page 41

1-34
1.14.3 Service Required Errors
A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the
alarm is silenced. The computer displays an error message from the list below three times with the
location of the error. Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen,
enter code 1111. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error
until issue is fixed.
Pressing the MIB reset button during any filter function will generate a “SERVICE REQUIRED”
error.
This is a list of the service required errors and causes.
ERROR MESSAGE
EXPLANATION
PUMP NOT FILLING
Oil not returning to vat quickly. Possible
problems: dirty pad, bad or missing O-rings,
tripped or defective filter pump, actuators or
linkage.
DRAIN VALVE NOT OPEN
Drain valve failed to open; the valve’s
position is unknown.
DRAIN
VALVE
NOT
CLOSED
Drain valve failed to close; the valve’s
position is unknown.
RETURN VALVE NOT OPEN
Return valve failed to open; the valve’s
position is unknown.
RETURN VALVE NOT CLOSED
Return valve failed to close; the valve’s
position is unknown.
MIB BOARD
Problem with CAN communications; Check
for loose CAN connections between
computer and MIB board. MIB board failure
AIF BOARD
MIB detects AIF missing; AIF board failure
ATO BOARD
MIB detects ATO board connection lost;
ATO board failure
HIGH LIMIT FAILURE
High limit circuit has an issue
AIF PROBE
AIF RTD reading out of range
ATO PROBE
ATO RTD reading out of range
TEMP PROBE FAILURE
TEMP Probe reading out of range
MIB SOFTWARE
Internal MIB software error
INVALID CODE LOCATION
SD card removed during update
MISCONFIGURED ENERGY TYPE
Energy type in fryer setup is incorrect. (ie.
Set proper energy type gas or electric)
Press 1234 to enter setup to properly
configure fryer.
RTC INVALID DATE
The date is invalid. Press 1234 to enter
setup to properly configure fryer and set
proper date.