KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7-3

7.2 Fryer Troubleshooting (cont.)

7.2.3

(cont.)

Actual frypot temperature
differs from computer
setpoint temperature.


5. The thermometer temperature should be

within ±10°F (±5°C) of the computer
display temperature.

Yes: System is maintaining temperature
properly.

Fr
ypot Fr

ont

High-Limit

Probe

Temperature

Probe


No: Ensure the probe tip is ⅛" from the
top of the burner tubes (see illustration).
If the probe adjustment is correct, the
computer probe circuit may be faulty. If
probe adjustment is incorrect, it will
require adjustment.


6. Contact your authorized service agent if

any of the following occurs during this
test:

a. Computer probe circuit is suspected

as faulty.


b. Temperature probe requires

adjustment.

c. Computer fails to call for heat

during the calibration test.














Burner Tube

Temperature Probe

Probe Bracket