9 safety switches (cont.) – Frymaster COOL ZONE SERIES KSCF18G User Manual
Page 25
KSCF18G COOL ZONE SERIES GAS FRYERS
CHAPTER 3: INSTALLATION INSTRUCTIONS
3-12
3.9 Safety Switches (cont.)
B. Other Fryer/Filter Switches
1. Drain Valve Microswitch: The computer
will display DRAIN OPEN when the
drain valve is opened. The computer will
lockout, preventing any cooking operation
until EXIT/COOL FILTER is pressed.
2. Float-Switch: Located in the frypot.
Designed as a safety switch, it deactivates
the gas valve, preventing burner ignition
until the oil level extends above the
heating tubes.
3. High-limit Reset: Located in the right
fryer cabinet under the control panel.
This switch is used to reset the high-limit
if the cooking medium has reached high
temperature safety limits. The high-limit
sensor bulb is mounted inside the frypot
between the two left-most burner tubes.
4. Manual Filter Override Switch: Also
located in the right fryer control panel of
the fryer battery. This rocker switch
(older units have toggle switches) allows
the operator to manually operate the
filtration system if a problem develops
with the auto filtration functions.
High-Limit
Probe
Temperature
Probe
Frypot Front
Float
Switch
A microswitch is located on the red handle at the
drain valve.