beautypg.com

3 filter operations (cont.) – Frymaster COOL ZONE SERIES KSCF18G User Manual

Page 40

background image

KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 5: FILTRATION

5-9

5.3 Filter Operations (cont.)


4. Use the L-shaped brush to scrub the frypot,

and to assist in sediment removal. Brush
down the frypot sides and between the tubes
to remove debris. Use the clean-out rod to
clear the drain if necessary.











5. Open the oil return valve by moving the

yellow handle from the closed position to the
open position (according to the yellow label).
When the yellow handle is moved, the filter
pump starts.

With the red drain valve handle still in the
open position, continue to scrub the frypot
sides and bottom.


WARNING

If the filter pump safety switch

repeatedly trips, do not continue to

reset. A potential safety hazard exists.

Contact an authorized service

technician for troubleshooting.

Note: A 7-amp or 5-amp circuit breaker located

under the control panel of the right-hand
fryer protects the filter circuit. A thermal
overload breaker is built in to the filter motor
in case of overheating/overload.

If the circuit breaker or the thermal overload
trips, the filter pump will stop. Reset the
appropriate breaker(s) and continue the
filtration process.






Use the L-shaped brush to loosen debris as oil
drains from the frypot.

Moving the yellow handle to the open position
opens the oil return valve and activates the filter
pump.

A resettable circuit breaker protects the filter
circuit.