Furuno 1933C User Manual
Page 248

SP - 4
E3503S02H-M
NMEA 0183 Ver1.5
GGA, GLL, RMA, RMC, GTD, VTG, ZDA (GPS data required)
RMB, WPL, BWC or BWR, APB, AAM, BOD, XTE, VHW, MTW,
DPT or DBT, DBS (ETR required),
TLL (L/L, Heading data required), TTM (ARPA required)
5
PLOTTER FUNCTION
5.1
Projection
Mercator
5.2
Usable Area
85 latitude or below
5.3
Effective Area
211.2 x 158.4 mm
5.4
Display pixels
640 x 480 dots
5.5
Position Indication
Latitude/longitude, Loran C LOP or DECCA LOP
5.6
Effective Projection Area 0.125 nm to 1,024 nm (at equatorial area)
5.7
Track Display
Plot interval: by time (1 sec. to 99 min. 59 sec.) or
by distance (0 to 99.9 nm)
5.8
Colors
Red, yellow, green purple, light-blue, blue, white
5.9
Memory Capacity
Track/mark: 8000 points, Waypoint: 999 points
5.10 Storage Capacity
Simple route: 200 routes with 35 waypoints each
5.11 MOB
1 point
5.12 Quick Routes
1 course with 35 waypoints max.
5.13 Electronic Chart
FURUNO chart card or NAVIONICS chart card available
C-MAP chart card also available for C-MAP NT Model
5.14 Alarms
Arrival and Anchor watch, Cross track error and proximity
alarms, Ship’s speed in and out alarms, Water temperature,
Trip alarm, Fish alarm, Bottom alarm (ETR required)
6
POWER SUPPLY
6.1
Rated Voltage/Current
M1823C
12-24 VDC: 5.5-2.7 A
M1833C
12-24 VDC: 5.3-2.6 A (6.4-3.1 A)
M1933C (24rpm)
12-24 VDC: 5.6-2.7 A (6.7-3.2 A)
M1933C (48rpm)
12-24 VDC: 7.5-3.6 A
M1943C (24rpm)
12-24 VDC: 6.3-3.1 A (7.4-3.5 A)
M1943C (48rpm)
12-24 VDC: 8.1-3.8 A
M1953C (24rpm)
12-24 VDC: 8.6-4.3 A
M1953C (48rpm)
12-24 VDC: 10.3-5.1 A
( ): for high brilliance monitor
6.2
Rectifier (option)
100-115/220-230 VAC, 1 phase, 50/60 Hz