beautypg.com

6 5.2.2 radar range setup – Furuno 1933C User Manual

Page 180

background image

5. CUSTOMIZING YOUR UNIT

5-6

5.2.2 Radar

range

setup

You may choose the radar ranges you wish to use, from the RADAR RANGE
SETUP menu. After choosing the ranges desired, change the range with the
[RANGE] key to activate range settings. Available ranges depends on the radar
used.

At least two ranges must be turned on. When less than two ranges are turned on
you cannot escape from the RADAR RANGE SETUP menu.

Note that this function is not available with the GD-1900C.

1. Press the [MENU] key to show the main menu.
2. Press the RADAR RANGE SETUP soft key to show the RADAR RANGE

SETUP menu.

RANGE
SETUP

ON/OFF

RETURN

RANGE
SETUP

ON/OFF

RETURN

Range unit: nm

Range unit: km

* = Max. range depends on network radar used and is set on the network radar at installation.

0.125nm
0.25nm
0.5nm
0.75nm
1nm
1.5nm
2nm
3nm
4nm
6nm
8nm

12nm
16nm
24nm
36nm
48nm
64nm
72nm

MAXIMUM RANGE XXnm

*

ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF

0.25km
0.5km
0.75km
1km
1.5km
2km
3km
4km
6km
8km

12km
16km
24km
36km
48km
64km
72km

MAXIMUM RANGE XXkm

*

ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF

Radar range setup menu

3. Use the trackball to select the range which you want to turn on or off.
4. Press the ON/OFF soft key to turn a range on or off as appropriate.
5. Press the RETURN soft key to register settings.
6. Press the [MENU] key to close the menu.

Model Maximum

Range

1823C

24 nm, km, sm

1833C

36 nm, km, sm

1933C

48 nm, km, sm

1943C

64 nm, km, sm

1953C

72 nm, km, sm