2-17

2.6 Control Box of Hull Unit

Connect the power cable TYPCY-4 (3

φ) and the transceiver unit cable (10S2078, end with

shorter peeled portion) as shown below.

Conductor

S = 4 mm

2

= 2.55 mm

Vinyl

sheath

Armor

Sheath

100

25

20

FV5.5-4

M4 (YEL) x 3

Vinyl sheath

Clamp
armor.

Anticorrosiove
sheath

Power cable
TPYCY-4

Cable 10S2078
(from transceiver unit)

LED (Red)
For detection of phase reversal on
3 phase power cable

Confirm LED after completing the installation. The LED lights (in red) if power connection is
correct. If it is off, turn off power from the mains switchboard, reconnect any two lines of the
power cable, turn on the power, and check if the LED is lit. The hull unit does not work if this
connection is wrong.

Normal phase: LED lights (in red).
Phase reversal: LED does not light.