6 control box of hull unit – Furuno FSV-84 User Manual
Page 45
2-17
2.6 Control Box of Hull Unit
Connect the power cable TYPCY-4 (3
φ) and the transceiver unit cable (10S2078, end with
shorter peeled portion) as shown below.
Conductor
S = 4 mm
2
∅
= 2.55 mm
Vinyl
sheath
Armor
Sheath
100
25
20
FV5.5-4
M4 (YEL) x 3
Vinyl sheath
Clamp
armor.
Anticorrosiove
sheath
Power cable
TPYCY-4
Cable 10S2078
(from transceiver unit)
LED (Red)
For detection of phase reversal on
3 phase power cable
Confirm LED after completing the installation. The LED lights (in red) if power connection is
correct. If it is off, turn off power from the mains switchboard, reconnect any two lines of the
power cable, turn on the power, and check if the LED is lit. The hull unit does not work if this
connection is wrong.
Normal phase: LED lights (in red).
Phase reversal: LED does not light.