4 error messages – Furuno DS-60 User Manual
Page 64

6. MAINTENANCE, TROUBLESHOOTING
6-4
6.4
Error Messages
The Distributor Unit monitors the system for error. When an error occurs, the audible
alarm sounds and an error message appears at the bottom of the display. You can
stop the audible alarm with the ALARM ACK key. The error message remains on the
screen until the reason for the error message is removed.
The table below shows all the error messages that can appear on the display.
The system displays one error message. If many errors occur at the same time, the
most important error message is displayed. See the table below for error message and
priority.
Error category
Unit, error
Error code
POWER FAIL
—-
100
SYSTEM FAIL
DS-620
B voltage circuit
210
B voltage
211
+5V voltage
212
+12 voltage
213
DS-340
Temperature (high)
220
Optical line
221
PI control
222
DS-610
Communication with DS-600
231
Communication with DS-620
232
SPEED ALARM
Speed alarm
300
ECHO FAIL
Echo
310
Error
Error message
POWER
FAIL
SYSTEM
FAIL
SPEED
ALARM
ECHO
FAIL
Alarm
—
—
—
POWER FAIL 100
No alarm
Alarm
—
—
SYSTEM FAIL 2xx
No alarm
No alarm
Alarm
No alarm
SPEED ALARM 300
No alarm
No alarm
No alarm
Alarm
ECHO FAIL 310
No alarm
No alarm
Alarm
Alarm
SPEED ALARM 300
ECHO FAIL 310
Error message