6. MAINTENANCE, TROUBLESHOOTING

6-3

6.3

Troubleshooting

This section provides the troubleshooting procedures that the user can follow to
restore normal operation. If you cannot restore normal operation, contact a qualified
FURUNO technician for instruction.

Problem

Possible cause

Action

General

The power cannot be
turned on.

Loosened power cable.

Fasten the power cable.

Blown fuse.

Get a qualified technician to
check the fuse in the
display unit. Replace the
fuse if it has blown.

The power is on, but
the screen is black.

The brilliance is too low.

Increase the brilliance.

Doppler speed indication

The indication does
not change (display
has frozen) and the
speed unit is red.

• Air bubbles on the transducer

face.

• The ground tracking mode is

used when the depth is 200 m
or more.

• Wait for the air bubbles

to disappear.

• Select the water tracking

mode or auto mode.

The indication shows
“-.--”

• Air bubbles on the transducer

face.

• The ground tracking mode is

in use when the depth is 200
m or more.

• Wait for the air bubbles

to disappear. If the prob-
lem continues, check the
transducer.

• Select the water tracking

mode or auto mode.

GPS speed, position indication

The indication shows
“-.--”

GPS data error.

Check the GPS receiver.

The indication shows
hyphens (-) at digit
locations.

The GPS receiver is
disconnected.

Check the GPS receiver.