beautypg.com

2 sense data analysis, 1 error information indicated with sense data – FUJITSU MAX3073FC User Manual

Page 97

background image

7.2 Sense Data Analysis

C141-E234

7-3

7.2

Sense Data Analysis

7.2.1

Error information indicated with sense data

Subsection 7.2.2 onwards explain troubleshooting using sense data. For details of the following
sense data, refer to Chapter 5 “Sense Data Error Recovery Methods” of the Fibre Channel Interface
Specifications.

Table 7.1 lists the definition of sense data. For details of sense data, refer to the Fibre Channel
Interface Specifications.

Table 7.1

Definition of sense data

Sense data

Sense

key

Additional
sense code

Additional
sense code

qualifier

Definition

00

00

00

Operation was normal.

3

0C

03

A write to a disk terminated abnormally.

4

32

01

Failed to update the defect list due to a disk medium write error,
etc.

40

xx

An error occurred in power-on self-diagnosis.

C4

xx

A drive error occurred.

1
3

1x
1x

xx
xx

A disk read error occurred.
A disk read error occurred.

E

1D

00

Data discrepancy found by VERIFY command byte check.

5

2x

xx

A SCSI error, such as an invalid operation code, occurred.

4 or B 44 xx A hardware error occurred inside

the HDD.

B

47

00

A CRC error occurred in the fibre channel loop.

49

00

An unmounted or inappropriate message was received.

4E

00

An overlap command was issued.

This manual is related to the following products: