MIB (Manual Interface Board) Display Diagnostics
DISPLAY
LED
EXPLANATION
Drain
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
On
Drain valve on vat # is open.
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
Off
Drain valve on vat # is closed.
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
Blink
Drain valve on vat # is opening or closing
or an error condition may exist.
Return
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
On
Return valve on vat # is open.
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
Off
Return valve on vat # is closed.
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
Blink
Return valve on vat # is opening or
closing or an error condition may exist.
Network
N
Network error, displays for 10 seconds in
no communications are received from the
M3000 within 10 seconds after power on
or MIB reset.
Resetting
r
An “r” is displayed for ten seconds or
until communication is received from the
M3000 after a power on or MIB reset.
Miscellaneous
E alternating with vat # (The vat number is followed
by an “L” to indicate left side of a split vat or an “r” to
indicate the right side of a split vat or a full vat.)
Blink
The circuit has an issue. Ensure the
actuator is plugged in. Ensure the CAN
connections are all securely plugged into
the connectors.
Indicates the AIF temperature sensor did
not detect a full vat during fi ltration.
A
Manual
LED off
The system is in auto fi ltration mode.
Vat # (The vat number is followed by an “L” to
indicate left side of a split vat or an “r” to indicate the
right side of a split vat or a full vat.)
Manual
LED on
The system is in manual mode.
P
This will only be displayed in auto
fi ltration mode. Filter pan is improperly
seated. Any auto fi ltration messages
received at this time are ignored.