LOV
™
Generation II Technical Reference
27
CODE
ERROR MESSAGE
EXPLANATION
E01
REMOVE DISCARD (Right)
A product cook is started on the right side of a split vat
or in a full vat that has a different setpoint other than the
current vat temperature.
E02
REMOVE DISCARD (Left)
A product cook is started on the right side of a split vat
or in a full vat that has a different setpoint other than the
current vat temperature.
E03
ERROR TEMP PROBE FAILURE
TEMP Probe reading out of range.
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is past more than 410°F (210°C),
or in CE countries, 395°F (202°C).
E06
HEATING FAILURE
A component has failed in the high limit circuit such as
computer, interface board, contactor or open-high limit.
E07
ERROR MIB SOFTWARE
Internal MIB software error.
E08
ERROR ATO BOARD
MIB detects ATO board connection lost; ATO board
failure.
E09
ERROR PUMP NOT FILLING
Oil not returning to vat quickly. Possible problems: dirty
pad, bad or missing O-rings, tripped or defective fi lter
pump, actuators or linkage.
E10
ERROR DRAIN VALVE NOT OPEN
Drain valve failed to open; the valve’s position is
unknown.
E11
ERROR DRAIN VALVE NOT CLOSED
Drain valve failed to close; the valve’s position is
unknown.
E12
ERROR RETURN VALVE NOT OPEN
Return valve failed to open; the valve’s position is
unknown.
E13
ERROR RETURN VALVE NOT CLOSED
Return valve failed to close; the valve’s position is
unknown.
E14
ERROR AIF BOARD
MIB detects AIF missing; AIF board failure.
E15
ERROR MIB BOARD
Cooking computer detects MIB connections lost;
check software version on each computer. If versions
are missing, check CAN connections between each
computer; MIB board failure.
E16
ERROR AIF PROBE
AIF RTD reading out of range.
E17
ERROR ATO PROBE
ATO RTD reading out of range.
E18
Not Used
E19
M3000 CAN TX FULL
Connection between computers lost.
E20
INVALID CODE LOCATION
SD card removed during update.
E21
FILTER PAD PROCEDURE ERROR
(Change Filter Pad)
25 hour timer has expired or dirty fi lter logic has
activated.
E22
OIL IN PAN ERROR
The MIB has detected oil may be in the pan.
E23
CLOGGED DRAIN (Gas)
Vat did not empty during fi ltration.
E24
OIL RETURN (level) SENSOR FAILED
(Gas)
Oil return sensor may have failed.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E26
RECOVERY FAULT CALL SERVICE
Recovery time exceeded maximum time limit for two or
more cycles.
E27
LOW TEMP ALARM
Oil temperature has dropped lower than 15°F (8°C) in
idle mode or 45°F (25°C) in cook mode.