Generation ii technical reference, M3000 useful codes – Frymaster LOV M3000 User Manual
Page 26

LOV
™
Generation II Technical Reference
25
M3000 Useful Codes
To enter any of the following codes: Press and hold
and
simultaneously for TEN seconds; three
chirps sounds. The computer displays
TECH MODE
TECH MODE. Enter the codes below to perform this function.
•
0042
0042 – Reset RECOVERY FAULT CALL SERVICE
RECOVERY FAULT CALL SERVICE.
•
1658
1658 – Change from F° to C°. The computer displays off
off. Turn the computer on and check
temperature to see the temperature scale. If the desired scale is not displayed, repeat.
•
3322
3322 – Reset Factory Menu. The computer displays COMPLETE
COMPLETE, and then off
off. (NOTE:
This will delete any hand-entered menu items.)
•
1650
1650 – Enter Tech Mode. See page 1-36 to reset passwords and change fi lter pad time.
•
1212
1212 – Switch Between Domestic and International Menu. The computer displays
COMPLETE
COMPLETE, and then off
off. (NOTE: This will delete any hand-entered menu items.)
•
0469
0469 – Reset Filter Stat Data
Filter Stat Data.
The following codes require the removal and reinsertion of the J3 locator plug on the rear of the computer
before entering the code.
•
1000
1000 – Reset CALL TECH
CALL TECH Message. Disconnect board locator plug (J10). Reinsert plug.
Enter
1000
1000. Computer display switches to off
off. Remove and then restore power to the computer
using the 20-pin plug.
•
9988
9988 – Reset BADCRC
BADCRC Message. Disconnect board locator plug (J10). Reinsert plug. Enter
9988
9988. Computer display switches to off
off. Remove and then restore power to the computer using
the 20-pin plug. Replace the computer.
The following codes are entered when prompted to do so or from an energy misconfi gured exception error.
•
1111
1111 – Reset SERVICE REQUIRED
SERVICE REQUIRED Message. Enter this when the issue is fi xed and you
are prompted to enter.
•
1234
1234 – Enter SETUP MODE
SETUP MODE from energy misconfi gured exception error. (This usu-
ally can be done without pressing the fi lter buttons if an error is displayed.)
Passwords
To enter level one, level two passwords – Press and hold the TEMP and INFO buttons simultane-
ously until
level 1
level 1 or level 2
level 2 is displayed. Release the buttons and ENTER
ENTER Code
Code appears.
•
1234
1234 – Fryer Setup, Level One, and Level Two.
•
4321
4321 – Usage Password.