Generation ii technical reference – Frymaster LOV M3000 User Manual
Page 23

LOV
™
Generation II Technical Reference
22
Problem
Probable Causes
Corrective Action
M3000 display shows
RECOVERY FAULT
RECOVERY FAULT
CALL SERVICE.
CALL SERVICE.
Recovery time exceeded maximum
time limit for two or more cycles.
Silence the alarm by pressing the 9
button. Clear the error using the code
on page 25. Maximum recovery for
electric is 1:40.
M3000 display
shows
ENERGY
ENERGY
MISCONFIGURED
MISCONFIGURED
Wrong energy type selected in
setup.
Press 1234 to enter setup and set
energy type for electric.
M3000 display shows
EXCEPTION ERROR
EXCEPTION ERROR
with the description on the
right.
An error has occurred.
Press 1234 to enter setup and
reconfi gure the computer.
M3000 displays
SERVICE
SERVICE
REQUIRED
REQUIRED followed by
the error
.
An error has occurred.
Press YES to silence alarm. The
error is displayed three times. See
list of issues on page 26. Fix issue.
The computer displays SYSTEM
SYSTEM
ERROR FIXED? YES/NO.
ERROR FIXED? YES/NO. Press
YES. Computer displays ENTER
ENTER
CODE
CODE.. Enter 1111 to clear error
code. Pressing NO will allow the fryer
to cook, but error will be redisplayed
every 15 minutes.
M3000 display is in
wrong temperature scale
(Fahrenheit or Celsius).
Incorrect display option
programmed.
See page 28 to change temperature
scale.
M3000 displays
CHANGE
CHANGE
FILTER PAD
FILTER PAD.
Filter error has occurred, fi lter pad
clogged, 24 hour fi lter pad change
prompt has occurred, or change
fi lter pad was ignored on a prior
prompt.
Change the fi lter pad and ensure the
fi lter pan has been removed from the
fryer for a minimum of 30 seconds.
Do NOT ignore CHANGE FILTER
CHANGE FILTER
PAD
PAD prompts.
M3000 display shows
INSERT pan
INSERT pan.
A. Filter pan is not fully inserted into
fryer.
B. Missing fi lter pan magnet.
C. Defective fi lter pan switch.
A. Pull fi lter pan out and fully reinsert
into fryer.
B. Ensure the fi lter pan magnet is in
place and replace if missing.
C. If the fi lter pan magnet is fully
against the switch and computer
continues to display INSERT
INSERT
pan
pan, switch is possibly defective.
M3000 display shows
hot-hi-1
hot-hi-1.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
This in an indication of a malfunction
in the temperature control circuitry,
including a failure of the high-limit
thermostat.
M3000 display shows
HI-
HI-
LIMIT
LIMIT.
Computer in high-limit test mode.
This is displayed only during a test of
the high-limit circuit and indicates that
the high-limit has opened properly.