Generation ii technical reference, Filter error flow chart – Frymaster LOV M3000 User Manual
Page 32
LOV
™
Generation II Technical Reference
31
Filter Error Flow Chart
This chart follows the process of clearing a
Filter Error
Filter Error prompt. The prompt is displayed when any of the
following occur:
1. a clogged fi lter pad,
2. a tripped or defective fi lter pump,
3. a leaky O-ring on the pick up tube,
4. a clogged pressure switch (gas fryer),
5. a failed drain valve/actuator, or
6. a failed return valve/actuator.
It is cleared by following the prompts.
If the computer displays
SERVICE
SERVICE
REQUIRED
REQUIRED, the fryer can be used in most
cases by answering
NO
NO when the prompt
for
SYSTEM ERROR FIXED? YES
SYSTEM ERROR FIXED? YES
NO
NO is displayed. The message repeats every
15 minutes until the issue is repaired and
error cleared by a technician. To clear the
error, enter 1111 after answering
YES
YES when
SYSTEM ERROR FIXED? YES NO
SYSTEM ERROR FIXED? YES NO
is displayed.
Change filter pad and
ensure filter pan is
pulled out for a
minimum of 30
seconds.
Fryer returns to
cook mode for 4
minutes or 15
minutes if pad
change expired.
NORMAL
OPERATION
RESUMES
SIXTH
CONSECUTIVE
FILTER ERROR
Fryer returns to
cook mode for 15
minutes.
TECH
ENTERS
CODE
MESSAGE
DISPLAYED
Call an Authorized
Repair Technician