ELECTRICAL POWER SPECIFICATIONS
Three (3) Phase Requirements
kW VOLTAGE
PHASE
WIRE
SERVICE
MINIMUM SIZE
AMPS PER LEG
AWG mm2 L1 L2
L3
17 208
3
3
6
16
48
48
48
17 240
3
3
6
16
41
41
41
17 480
3
3
6
16
21
21
21
17 220/380
3 4 6
16
26
26
26
17 240/415
3 4 6
16
24
24
24
17 230/400
3 4 6
16
25
25
25
21 208
3
3
4
25
57
57
57
21 240
3
3
4
25
50
50
50
21 480
3
3
6
16
25
25
25
21 220/380
3 4 6
16
N/A
N/A
N/A
21 240/415
3 4 6
16
29
29
29
21 230/400
3 4 6
16
27
27
27