Frymaster FOOTPRINT RE80 User Manual
Page 11
1-6
1
4
2
5
3
6
1
4
2
5
3
6
7
8
9
5
R
4R
6
R
1R
2
R
3R
Index Marker marks
Position 1
5L
4L
6L
1L
2L
3L
9. Reconnect the element connector ensuring that the latches lock.
10. Insert the temperature probe leads into the 12-pin wiring harness connector C-6 (see illustration
below). For full-vat units or the right half of a dual-vat unit, the red lead goes into position 3 and
the white into position 4. For the left half of a dual-vat unit, the red lead goes into position 9 and
the white into position 10. NOTE: Right and left refer to the fryer as viewed from the rear.
10. Reconnect the 12-pin connector C-6 of the wiring harness disconnected in Step 2.
11. Lower the element down onto the basket rack.
12. Reinstall the tilt housing, upper cover and back panels, reposition the fryer under the exhaust
hood, and reconnect it to the electrical power supply.
1.7 Replacing Contactor Box Components
1. If replacing a contactor box component above the built-in filter system, remove the filter pan and
lid from the unit. Drain the frypots into a Shortening Disposal Unit (SDU) or other appropriate
metal container. If replacing a contactor box component in a non-filter unit or a frypot that’s not
over the filter pan, drain the frypot above the box into a Shortening Disposal Unit (SDU) or other
appropriate metal container.
DANGER
DO NOT drain more than one full frypot or two split frypots into the SDU at one time.
2. Disconnect the fryer from the electrical power supply.
3. Remove the two screws securing the cover of the contactor box. The contactor boxes above the
filter pan are accessed by sliding under the fryer. They are located to the left and right above the