To confirm the location of an rci i/o unit, 3 replacing an rci i/o unit, To confirm the location of an rci i/o unit: -10 – FUJITSU SPARC M3000 User Manual

Page 36: Replacing an rci i/o unit -10

background image

2-10

C120-E360-06EN

CHAPTER 2 Setup of the RCI for Operation

3

Execute the setrci (8) command to display a list of connected RCI units.

On the list, "INACT" is displayed in the "I/F" column of the RCI I/O unit that cannot
make a transmission to the RCI.

• To confirm the location of an RCI I/O unit:

If the RCI address of the target RCI I/O unit is already known, such as because of an
error message, the location of the RCI I/O unit can be confirmed by specifying its RCI
address and triggering blinking of its LED.

1

Execute the setrci (8) command to trigger blinking of the LED of the RCI I/O
unit at the specified RCI address.

2

Locate the RCI I/O unit whose LED is blinking.

3

Execute the setrci (8) command to stop the blinking LED of the RCI I/O unit.

2.5.3

Replacing an RCI I/O Unit

Remove the T-branch connector together with the RCI cables from the RCI I/O unit to
be replaced. Replace the RCI I/O unit, and connect the T-branch connector and RCI
cables to the new RCI I/O unit.

XSCF> setrci -c stat
HOST
address 000102ff
Active
LIST
address pwr alm I/F sys-phase tgry dev-cls sub-cls tm-out
000101ff OFF - ACT - host 0001 0b -
003001ff OFF - ACT - disk 0400 04 -
003002ff OFF - INACT - disk 0400 04 -
003003ff OFF - ACT - disk 0400 04 -
The command completed successfully.

Specifying the RCI address 003002ff
XSCF> setrci -c ledon <003002ff>
.....
The command completed successfully.

XSCF> setrci -c ledoff
The command completed successfully.