CHAPTER 1 RCI Overview

Figure 1.4

shows a connection pattern that connects both duplicated and unduplicated

configurations.

Figure 1.4 Mixture of duplicated and unduplicated configurations

The pattern can contain RCI I/O units and RCI hosts that do not support a duplicated
configuration.

Connect them to the duplicate system. Connect RCI hosts that do not support a
duplicated configuration to the #0 system.

If an RCI host that does not support a duplicated configuration were already
connected, RCI I/O units would be connected to the #0 system.

Note:

When an RCI host of the duplicated configuration is connected with RCI
hosts or RCI I/O units that do not support a duplicated configuration, it may
fail to control the RCI host or the RCI I/O unit on the #0 system in the
following case:

z When an XSCFU#0 failure generated an XSCF failover and the Active

XSCF Unit switched to XSCFU#1.

In this case, maintenance work of XSCFU#0 becomes necessary.