22

Installation instructions

Power supply cord requirements for U.S.A (for electric models only)

Only a UL listed power-supply cord kit a suitable length for the installation and rated 120/240 V
min, 30 A and marked with use for clothes dryers shall be used.

This shall have ring terminals to connect to the dryer.

The UL-rated strain relief included with it shall be suitable for a 1 1/8” (28.5 mm) hole.

Fig.20 UL listed power-supply cord

If your outlet looks like this

Choose this power supply cord

3 wire

4 wire

Connecting by direct wire

Power supply cable must match power supply (4-wire or 3-wire) and be:

Flexible armoured or non-metallic sheathed copper cable (with ground wire). All current-
carrying wires must be insulated.

10 gauge AWG solid copper wire (do not use aluminium wire).

Suitable length for the installation.

A UL approved strain relief must be used.

Grounding for a direct wired appliance

This appliance must be connected to a grounded metal permanent wiring system, or an
equipment grounding conductor must be run with the circuit conductors and connected to the
equipment-grounding terminal on the appliance.