beautypg.com

FUJITSU C150-E187-01EN User Manual

Page 32

background image

26

Double Feed Detection

This option detects a double feed (occurs when two or more documents are sent) based on
the set condition.

If a double feed is detected when this setting has been turned on, the device will stop and an
error message output.

None

Double feed detection is not performed.

Hardware Setting

A double feed is detected based on the device setting.

Check thickness

The thickness of the transmitted document is checked by the sensor in the device. A
double feed is detected by detecting changes in the thickness when more than one
document is sent.

Check length

The length of the transmitted document is checked by the sensor in the device. A double
feed is detected by detecting changes in the length when more than one document is sent.

Check thickness and length

The thickness and length of the transmitted document are checked.

The detection accuracy can be improved by using [Check thickness] for continuous scanning
of forms that have different lengths and [Check length] for scanning of forms that have
different thicknesses.

Blank page skip

This option skips blank pages (blank pages or completely black pages) during ADF
continuous scanning.

For blank pages, use the [White Dots Ratio] slider to set the skip condition. For black pages,
use the [Black Dots Ratio] slider to set the skip condition.

The value displayed to the right of the slider displays the garbage ratio(*1). If a scanned
document is below this value, it is recognized as a blank page. The setting range is OFF(- -)
and 0.2% to 3.0% (in increments of 0.2%).

If a blank page is scanned, increase the value set.

If scanning is skipped up to the required document, decrease the value set.