8

D. Inspect Appliance and Components

C. Tools and Supplies Needed

Before beginning the installation be sure that the following
tools and building supplies are available.

Reciprocating saw

Framing material

Pliers

Hi temp caulking material

Hammer

Gloves

Phillips screwdriver

Framing square

Flat blade screwdriver Electric drill and bits (1/4 in.)

Plumb line

Safety glasses

Level Tape

measure

Manometer Voltmeter

Non-corrosive leak check solution

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

One 1/4 inch female connection (for optional fan).

Inspect appliance and components for
damage. Damaged parts may impair safe
operation.

• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.

Report suspected damaged parts to dealer.

• Carefully remove the appliance and components from

the packaging.

• The vent system components and trim doors are shipped

in separate packages.

• The gas logs may be packaged separately and must be

fi eld installed.

• Report to your dealer any parts damaged in shipment,

particularly the condition of the glass.

Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:

• Installation and use of any damaged appliance or vent

system component.

• Modifi cation of the appliance or vent system.

• Installation other than as instructed by Hearth & Home

Technologies.

• Improper positioning of the gas logs or the glass door.

• Installation and/or use of any component part not

approved by Hearth & Home Technologies.

Any such action may cause a fi re hazard.

Figure 2.2 Typical Vertical Installation

The following B-vent components are needed for installa-
tion (see Figure 2.2).

• Fireplace Box

• Pipe Components

• Firestops

• Attic Insulation Shield

• Elbows

• Strapping

• Roof Flashing or Chase Top

• Termination Cap

• Storm Collar

Read all of the instructions before starting the instal-

lation. Follow these instructions carefully during the
installation to ensure maximum safety and benefi t.

VERTICAL TERMINATION CAP

STORM COLLAR

ATTIC INSULATION SHIELD

GAS B-VENT

PIPE SECTION (S)

FIRESTOP SPACER

ROOF FLASHING
OR CHASE TOP

WARNING

WARNING