High Pressure Switch**
stops the pump when
the pressure of the tank filled with clean water
reaches 2.6 bar (38 psi).
Clean Water Tank
inner surface is coated with
a "food contact" plastic material suitable for
food and enables clean water to be stored in a
hygienic environment. Tank Valve controls the
water inlet and outlet to/from the tank.
Mineral Carbon Filter (340005Z06)
provides mineral to the clean water collected in
tanks or directly from the membrane before if
flows from the faucet, enriches the water and
regulates the pH. THROTTLE ensures formation of
required pressure in the membrane by restrict-
ing flow so that the membrane can perform the
separation process. It is located on the line where
the waste water is drained.
Clean Water Faucet
is where clean water is
taken.
Pump Adapter**
is the power supply of the
pump, it converts the mains
voltage to 24 V DC.
Solenoid Valve*
controls the flow of water.
When the water pressure in the tank reaches a
certain value, it closes the water inlet and
prevents water being consumed unnecessarily.
Digital Display*
is used for tracking the life of
each filter based on the water passed throug the
filters. When the filter life is over, the water is cut
or in case of a water
leakage it alerts the user.
Flow meter*
is used in determining the amount
of water passing through the filters and monitor-
ing the current flow rate.
Water Leakage Sensor*
detects water leakage
and blocks the water inlet of the system.
Water Leakage Shut off Closes
the water
inlet mechanically in case of water leakage.
* Applicable for 101 ME model.
** Applicable for 101 ME and 101 MD models.
*** Applicable for 101 MD and 101 FG models.
Fields of use
This appliance is used to obtain drinking water from the mains water that have passed
through the municipal treatment processes. This water should be microbiologically safe,
subjected to the necessary disinfection.
If the parameters of the water are within the following ranges efficient operation of the
appliance is ensured. Systems designed differently for waters such as sea water, well
water, muddy water etc. with a very high TDS value are also available.
40 psi-145 psi / (2,8 bar-10 bar) / (275 kPa - 1.000 kPa)
3-11
MAXIMUM FE
0,2 (ppm=mg/L)
MAXIMUM TDS
1250 (ppm=mg/L)
5 NTU
5˚C - 38 ˚C / (38 ˚F - 100 ˚F)
TEMPERATURE
OPERATING PRESSURE
PH RANGE
TURBIDITY
17˚Fr-10 ˚dH - 170 mg/L CaCO3
HARDNESS
# Max. pressure matches the structural integrity test value of NSF/ANSI Standard 58 for 101ME model