Reverse osmosis (ro) water treatment systems – İhlas Aura Cebilon Unique User Manual
Page 5

5
Reverse osmosis (ro) water
Treatment systems
* Applicable for 101 ME model.
** Applicable for 101 ME and 101 MD models.
There are systematic appliances available to obtain low concentration
water from high concentration water by using the reverse osmosis
method.
It is possible to reverse osmosis which is a natural event. When the
pressurized water is passed through the membrane wrapped as an
artificial roll, most of the solid particles are retained and discharged with
the waste water, the water that passes through the thin membrane is used
as drinking water. Before water enters the membrane, pre-filtration
processes such as sediment filter, carbon filter are carried out to retain
the coarse residues and the chlorine used in the water disinfection.
Components such as these filters used before and after membrane,
fittings connecting these together, pumps and switches used to
increase pressure, clean water storage tank and housing etc.
constitute a compact system. This system may have various
configurations. Mainly, pre-filtration is composed of reverse
osmosis in the membrane, pH regulation and water
storage processes which are the main elements of the
system.
Aura Unique Cebilon RO system consists of 3
interconnected pre-filters, membrane, pH regulator
last filter, digital control group*, pump ssembly and
water tank
Druck
After the osmosis
Pressure
Figure 1. Osmosis and Reverse Osmosis