Troubleshooting – İhlas Aura Cebilon Unique User Manual

Page 17

background image

17

Troubleshooting

** Only applies to 101 ME and 101 MD models.

* This table only applies to 101ME model.

Foam in water or

milky coloured

water.

Low water from the

appliance.

No water is received

from the faucet despite

the tank is full.

There is noise in the

appliance.

The pump is running

continuously.**

Air in the system.

Pump is not operating and there is

no sufficient pressure.**

There is bending, crushing on the

hoses.

Pre-filter group is clogged.

Membrane does not perform well.

Inlet water temperature dropped.

Check valve is defective.

Tank storage air pressure is

insufficient.

Regulator

Waste water hose may

make noise.

This may occur due to clogging and

bending of the waste water hose.

High Pressure Switch may be

defective.**

Low Pressure Switch may be defective.**
Check valve may be defective.
Shut off valve may be defective.
Pump may be defective.

Air in the system is a normal occurrence after

initial installation. Sometimes, air caused by

the mains may exist. This will return to

normal after usage for a while. There is no

inconveniency for using this water.

Check whether the pump adaptor is

plugged in. If adaptor is plugged in, consult

to your service.**

Check all the hoses connected to the

appliance, eliminate bendings, if any.

Please consult the service.

Please consult the service.
This is not a fault. Decrease in clean

water is normal during winter.

Please consult the service.

Insufficient air in the tank. Please

consult the service.

Clean the clogging of the drain hose or

straighten the bended hose.

Close the inlet water and consult to your

service.
Close the inlet water and consult to your service.

Please consult the service.

PROBLEM

POSSIBLE CAUSES

RECOMMENDED SOLUTION

EO is shown on the

display and the

appliance does not

provide water.

(Figure10a)

There is no mains water.

Filter life is completed.

E1 will be shown on the

display (Figure 10b).

Close the ball valve since there is no clean

water supplied to the mains after water is cut.

When the water returns, open the ball valve

after the mains water starts to flow clean.

Your appliance will be ready to use.

Please consult the service.

Water leakage is detected.

E2 will be shown on the

display (Figure 10c).

Please consult the service. Close the ball

valve and cut the water inlet.

It indicates that the filter life is nearly

completed.

Please consult the service.

icon is shown on the
display (Figure 10d).

If regulator setting pressure is equal to the mains

water, this may make noise. The noise will stop

when mains pressure is back to normal.
Make the position of the clamp attached to the

flush and the waste water hose passing through

it proper.