Troubleshooting – İhlas Aura Cebilon Unique User Manual
Page 17

17
Troubleshooting
** Only applies to 101 ME and 101 MD models.
* This table only applies to 101ME model.
Foam in water or
milky coloured
water.
Low water from the
appliance.
No water is received
from the faucet despite
the tank is full.
There is noise in the
appliance.
The pump is running
continuously.**
Air in the system.
Pump is not operating and there is
no sufficient pressure.**
There is bending, crushing on the
hoses.
Pre-filter group is clogged.
Membrane does not perform well.
Inlet water temperature dropped.
Check valve is defective.
Tank storage air pressure is
insufficient.
Regulator
Waste water hose may
make noise.
This may occur due to clogging and
bending of the waste water hose.
High Pressure Switch may be
defective.**
Low Pressure Switch may be defective.**
Check valve may be defective.
Shut off valve may be defective.
Pump may be defective.
Air in the system is a normal occurrence after
initial installation. Sometimes, air caused by
the mains may exist. This will return to
normal after usage for a while. There is no
inconveniency for using this water.
Check whether the pump adaptor is
plugged in. If adaptor is plugged in, consult
to your service.**
Check all the hoses connected to the
appliance, eliminate bendings, if any.
Please consult the service.
Please consult the service.
This is not a fault. Decrease in clean
water is normal during winter.
Please consult the service.
Insufficient air in the tank. Please
consult the service.
Clean the clogging of the drain hose or
straighten the bended hose.
Close the inlet water and consult to your
service.
Close the inlet water and consult to your service.
Please consult the service.
PROBLEM
POSSIBLE CAUSES
RECOMMENDED SOLUTION
EO is shown on the
display and the
appliance does not
provide water.
(Figure10a)
There is no mains water.
Filter life is completed.
E1 will be shown on the
display (Figure 10b).
Close the ball valve since there is no clean
water supplied to the mains after water is cut.
When the water returns, open the ball valve
after the mains water starts to flow clean.
Your appliance will be ready to use.
Please consult the service.
Water leakage is detected.
E2 will be shown on the
display (Figure 10c).
Please consult the service. Close the ball
valve and cut the water inlet.
It indicates that the filter life is nearly
completed.
Please consult the service.
icon is shown on the
display (Figure 10d).
If regulator setting pressure is equal to the mains
water, this may make noise. The noise will stop
when mains pressure is back to normal.
Make the position of the clamp attached to the
flush and the waste water hose passing through
it proper.