No:

14

15

16

17

18

19

20

21

22

23

24

25

26

27

Possible Cause:

Gap between fold plate and fold
rollers not set correctly

Fold roller gap too narrow

Delivery table plug not connected

Voltage supply 30V in second fold
unit defective

Different paper thickness

Sheets from another folding job in
stack

Sheet gap too small

Air flow too weak

Counting photodetector sometimes
does not recognize sheets

Counting photodetector does not
count

Drive belts in delivery section
defective

Automatic setting of fold not yet
completed

Round belt in register table defective

The safety switch for the feed table
has been activated - the folder is not
ready for operation

Remedy:

Move fold plate to base position with
the help of the scales

Increase fold roller gap by turning
setting knob. Example: Turn scale at
setting knob from 0.10 to 0.20

Plug connection cable into adjacent
fold unit

Replace fuse T4A

Re-adjust for paper thickness

Remove sheet

Increase sheet gap

Adjust air flow

Move photodetector to another position
or check for proper function

Check connections, clean photodetector

Replace drive belts

Wait until fold is set

Replace round belt

Lower the feed table to reset - the fol-
der is again ready for operation