beautypg.com

Lingenfelter L460330000 Micro Storm MS-001 2-Stage Dual Ramp Progressive Nitrous Controller v 2.6 User Manual

Page 8

background image

8

21—Nitrous OFF rpm: This is the maximum RPM that the nitrous will be active. If there is no tach input
signal this feature is disabled. This setting MUST be greater than the Nitrous On RPM.

Valid range is 0 to 16,000 RPM in 100 RPM increments.

22—Timer / Shift Light Select: This setting determines if the Relay Output (purple wire) functions as a
Timer with Delay or a RPM controlled Shift Light Output.

0 = Timer function
1 = Shift Light function.

23—Timer delay or Shift RPM

Timer function selected: Delay in seconds before the output turns on.

Valid range is 0.00 to 9.99 in .01 second increments.

Timer starts when Activation criteria are met (TPS %, RPM, clutch/trans brake input)

Timer resets or resumes depending on Resume Mode (10) setting

Shift Light function selected: RPM that output will turn on.

Valid Range is 0 to 16,000 RPM in 100 RPM increments.

24—Turn dual ramp option ON/OFF: This setting can be used to enable a dual ramp feature. When the
dual ramp feature is ON there is a second final percentage and a second build time for each stage of nitrous.
This feature can be used to limit nitrous power during launch and then use the second ramp to aggressively
apply power once the vehicle is moving and weight transfer has occurred.

Example—Start% = 20, Final% 1 = 35, Build Time1 = 2.5 seconds, Final% 2 = 100, Build Time2 = 1 second.

0 = Dual ramp option off.
1 = Dual ramp option on.