Parameters – Lingenfelter L460330000 Micro Storm MS-001 2-Stage Dual Ramp Progressive Nitrous Controller v 2.6 User Manual
Page 5

5
Parameters
1—Current Setup: This setting controls which setup is active. Valid range is 1 to 5 in increments of 1.
Stage1 settings:
2—Nitrous Delay Time Stage1: This setting controls the delay time in seconds for nitrous stage1 to activate.
Valid range is 0.00 to 9.99 in increments of .01 second.
3—Nitrous Start Percent Stage1: This setting controls the start percentage for nitrous stage1. If there is a
delay value programmed for stage1 the start percentage will not be applied until the delay timer has expired.
Use this value to control the initial nitrous power applied.
Valid range is 10% to 100% in 1% increments.
4—Nitrous Final Percent1—Stage1: This setting controls the final nitrous percentage applied for Stage1 if
the “Dual Ramp” feature is OFF. The nitrous output will ramp from the Start percentage to the Final
percentage and the ramp time is controlled by the Build Time setting. The Final Percent can be lower than
the Start Percent, allowing for power to be taken away over time if desired.
Valid range is 10% to 100% in 1% increments.
5—Nitrous Build Time1—Stage1: This setting controls the time it takes stage1 to go from the starting
percentage to the final percentage. The nitrous will progressively ramp from the start to final setting in the
time programmed for this parameter. A shorter time (example 0.2 second) will create a very aggressive ramp
and a longer time (example 9.9 seconds) will create a smoother application of power.
Valid range is 0.0 second to 9.9 seconds in .1 second increments.
Stage2 settings:
6—Nitrous Delay Time Stage2: This setting controls the delay time in seconds for nitrous stage2 activation.
Valid range is 0.00 to 9.99 in increments of .01 second.
7—Nitrous Start Percent Stage2: This setting controls the start percentage for nitrous stage2. If there is a
delay value programmed for stage2 the start percentage will not be applied until the delay timer has expired.
Use this value to control the initial nitrous power applied.
Valid range is 10% to 100% in 1% increments.
8—Nitrous Final Percent1—Stage2: This setting controls the final nitrous percentage applied for Stage2 if
the “Dual Ramp” feature is OFF. The nitrous output will ramp from the Start percentage to the Final
percentage and the ramp time is controlled by the Build Time setting. The Final Percent can be lower than
the Start Percent, allowing for power to be taken away over time if desired.
Valid range is 10% to 100% in 1% increments.