Lingenfelter L460330000 Micro Storm MS-001 2-Stage Dual Ramp Progressive Nitrous Controller v 2.6 User Manual
Page 4

4
“Global” parameters are settings that are applied no matter which setup is selected.
“Current”
setup
parameters are settings that control the individual nitrous stages. Such as delay, start
percent, final percent, etc. There are five setups available, this allows the user to change between pre-
programmed nitrous setups easily. Parameter #1 controls which setup is selected (currently active).
“ESC” buttons refers to pressing the “ENTER” and “DOWN” buttons at the same time.
Ready mode: The controller must be in Ready mode to be activated. This is the default mode when the
unit is powered up. The display will read “r 1” if the current setup is #1. “r 2” for setup #2, etc…
The “Current Setup” can be changed from the ready screen by pressing and holding either the “UP” or
“DOWN” button for 2.5 seconds.
To return all of the settings to factory default press and hold the “ESC” buttons for 20 seconds while in ready
mode.
Programming mode: To enter programming mode the controller must be in the ready state. The display
will read “r 1” if the current setup is #1. “r 2” for setup #2, etc… To get to the ready screen press the “ESC”
buttons. The ready screen is also the default screen when the unit is powered up.
From the ready screen press and hold the “ENTER” button for 2.5 seconds. When the display reads “PPP”
release the button. The first parameter will now be selected and the display will read “P. 1”, use the “UP”,
“DOWN” buttons to scroll through all of the parameters. The parameter count will roll over if the minimum
or maximum selection is exceeded. This allows for quick access to the optional Dual Ramp parameters if they
are turned ON.
Once the desired parameter has been selected press and hold the “ENTER” button for 1 second. When the
display reads “PPP” release the button. Use the “UP”, “DOWN” buttons to adjust the setting. The new setting
is automatically saved as it adjusted. Press and hold the “UP”, “DOWN” buttons for accelerated adjust rate.
Press the “ENTER” button to return to the parameter selection menu.
Continue selecting and adjusting any parameters that need to be set. You can exit the programming mode at
any time by pressing the “ESC” buttons. Note—you do NOT have to go through all of the settings.
Live Data mode: To enter live data mode the controller must be in the ready state. The display will read “r
1” if the current setup is #1. “r 2” for setup #2, etc… To get to the ready screen press the “ESC” buttons. The
ready screen is also the default screen when the unit is powered up.
From the ready screen press and hold both the “UP” & “DOWN” (COMBO) buttons for 2.5 seconds. When the
display reads “0.00” release the buttons. The display will now show the signal voltage applied to the
Activation/TPS input. If a voltage greater than 5.00 volts is applied the display will read a maximum of 5.00
volts. No damage will be done if a +12 volt signal is applied to this input.
Press the “DOWN” button to display engine RPM and the “UP” button to return to activation input voltage.
Press “ESC” buttons to exit to the ready screen.