beautypg.com

Lingenfelter L320061410 Lingenfelter High Capacity Intercooler Heat Exchanger Camaro SS & ZL1 v1.1 User Manual

Page 15

background image

Page

45. Insert the three ground wires there, reinstall

the bolt and tighten to 18 lb-ft (25 Nm).

46. Set the operating temperatures on the

TBRC-001. Recommended temperatures

are 90 degrees for fans on low and 110 for

fans on high with a 10 degree hysteresis

as shown in the picture to the left. Do this

by turning the knobs for Temp 1 to 0 on the

x100 and 9 on the x10; 1 on the x100 and 1

on the x10 for Temp 2 dials; and 1 on the 16

option dial.

47. Hold the TBRC-001 up to where you would

like it mounted. A recommended location is

the metal flange just to the passenger side

of the fuse box.

48. Clean the surface well with brake clean or

equivalent and a paper towel or air hose.

14.