Reference
Remarks: xxx can be any valid register number. The data is transmitted in the form:
nnnnnnnnn
blanked.
Example: the net weight is 1945 lb. The indicator receives R66
contents of the Net weight register in the form
RTxxx
Purpose
the RT command.
Remarks: network systems are normally setup in a master/slave configuration. The master units
sends an RT command to the slave unit. The slave unit returns an RQ reply (RQ
true if scale weight is printable (handbook 44), stores the nnnn data into register 15, , and
then executes Scale Basic function 15.
Example: transfer the Net weight from station 25 to the master unit. In the Master unit
configure the following:
Set print label 32 = N
Note: this uses Memory10 for station ID. If Memory10 contains 25 then the following
would be sent: N25
Transmit of register 66 (Net weight).
Fn. 1:
Set Memory10, 25
Memory10 = station ID 25
Txcom2, Label32
Transmit RT request to station 25
End
End
of
function
The receipt of an RQ reply from the slave unit causes the slave’s Net weight to be stored in
register Memory15 and function 15 is automatically invoked.
Fn. 15:
If, Qstatus
If received data is printable weight
Copy Memory1, Memory15
Memory1 = Unit25’s Net weight
Else
Else
Set
Memory1,
0 Memory1
=
0
End
if
End
if
End
End
of
function
NOTE: On the slave station, only parameter 27 (station ID) needs to be configured. All
other functions in the slave operate automatically and in the background.
RWxxx
Purpose
Remarks: xxx can be any valid register number.
Example: the indicator receives: RW5
now contains 150.00.