beautypg.com

Gosub (function no.) 243 [nnn, Goto (function no.) 244 [nnn – Industrial Data Systems IDS Scale Basic User Manual

Page 26

background image

Scale Basic 4.2E

Reference

Get id, Memory1

Open Id 25

If, Zero

If the Id was not found

Error msg, 8

display error message 8

End

if

End

if

End

End

of

function

Gosub

(function

no.)

243

[nnn]

Purpose: to execute a function (subroutine) from within a function and return to the calling

function at the instruction after the Gosub instruction.

Remarks: a subroutine can be called from within a subroutine (this is called nesting). The

maximum level of nesting is 8; i.e. function1

function6

→ function7 → function2 …

maximum = 8 levels.


Example: in a bulk-weigh function the scale is zeroed, the display is set to Net mode, and relay1

is turned on.

Gosub,

Zero

Zero

the

scale

Gosub, Set net

Set the display to net mode

Relay on, 1

Turn on relay 1

End

End

of

function

Goto

(function

no.)

244

[nnn]

Purpose: transfer execution from one function to another.
Remarks:

Example:

If, Flag4

If flag4 is on

Goto,

7 Go

to

function

7

End

if

End

if

Set pt, On, 2

Turn on setpoint 2. This instruction is not

executed if Goto was executed.

If (condition) / Else / End if

241 [nnn] / 251 / 240

Purpose: to control program flow using a condition code.
Remarks: the instructions after the if statement are executed if the condition code is true, the

instructions after the Else statement are executed if the condition code is false. The Else part
of the instruction is optional. The End if statement ends the If statement.


Example: the F1 key (activates function1) is used to toggle the display between net weight and

memory1 (total). Flag1 is used to determine the current state of the display, Flag1 = True =
display total.

If, Flag1

If current mode = display total

Flag

off,

1

turn

off

flag

1

Display

Net

set

to

display

Net

weight

Else

Else

mode

not

display

net>