Update alt 145, User1…user15 1…15, Zero 130 – Industrial Data Systems IDS Scale Basic User Manual
Page 42: Events, Keyboard events, Setpoint monitors, Keyboard events setpoint monitors

Scale Basic 4.2E
Reference
Loop1
While
-
If Motion
Motion on scale
Update
Update
scale
readings
Next1
End
-
End
if
While
Motion
Gosub
Print1
page
1
Update
alt
145
Purpose: update alternate weight units registers.
Remarks: the indicator is designed provide weights in 2 units of measure: primary and alternate
units. The all weight calculations are performed in the primary weight units. The alternate
unit weights are only calculated as needed. If you use alternate units in Scale Basic functions,
the Gosub Update alt before using the alternate weight registers.
User1…User15
1…15
Purpose: provide user programmable functions.
Zero
130
Purpose: to zero the weight on the scale.
Remarks: condition code Positive is true if successful. The gross weight must be within the
configured zero range and the scale must be stable for this function to succeed. This is the
default function for the Zero key.
Events
Keyboard Events
Purpose: to execute a Scale Basic function when a key is pressed. A key-press event occurs
when a function key (PRINT, UNITS, GROSS/NET, TARE, F1, F2) is pressed.
Setpoint Monitors
Purpose 1: to monitor 2 registers and activate a scale basic function when the lower register is
greater than or equal to the upper register ( trigger when: lower register >= upper register ).
Purpose 2: to monitor a condition code and activate a scale basic function when the condition is
true or false. Set the upper register to True or False then the lower register to a condition
code.
Remarks: Setpoint monitors are activated using the Scale Basic instruction: Setpoint On [x].
There are 16 setpoint monitor records that contain the following data:
Upper register [P0] the upper value register, setpoint triggers when lower >= upper
Lower register [P1] the lower value register
Scale Basic Function [P2}
the scale basic function to execute when lower >= upper
Use the EZ Link button ‘Setpoint Events’ or the indicator configuration function 71 to enter
setpoint parameters.