4 result and error codes, 5 security commands, Result and error codes – Kramer Electronics PL-50 User Manual
Page 44: Security commands, Kramer protocol 3000
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol 3000
40
UPGRADE
Cmd Short
Description
Command Type
Permission
Execute firmware upgrade
Common
Administrator
Usage:
Syntax
Response
UPGRADE
UPGRADE OK
Firmware usually uploads to a device via a command like LDFW. The device may need to be reset to complete
the process.
10.4 Result and Error Codes
Syntax
Command ran successfully, no error.
COMMAND PARAMETERS OK
Protocol Errors:
Syntax error
ERR001
Command not available for this device
ERR002
Parameter is out of range
ERR003
Unauthorized access (command run without the matching login). ERR004
10.5
23B
Security Commands
LOGIN
Cmd Short
Description
Command Type
Permission
Login
Security
No Security
Usage:
Syntax
Response
LOGIN ID , PASS
ID = User/Admin
PASS = 0-15 length ASCII characters without #, ~, @, ?
LOGIN ID , PASS RESULT
LOGIN?
Cmd Short
Description
Command Type
Permission
Query Login
Security
No Security
Usage:
Syntax
Response
LOGIN?
LOGIN ID
LOGOUT
Cmd Short
Description
Command Type
Permission
Logout
Security
No Security
Usage:
Syntax
Response
LOGOUT
LOGOUT RESULT